K12230 High Temperature Oxidation Bath, Convertible

Test Method
Various methods are available for testing the resistance to oxidation and/or the corrosiveness of lubricants, insulating oils, hydraulic oils and distillate fuel oils. The samples are subjected to a metered flow of air at elevated temperatures, sometimes in the presence of a metal catalyst.

Features and Benefits
• Conforms to various ASTM, Federal and International Standards

• Removable racks hold different types of glassware for different tests

• Equipped with flowmeters or digital mass flow controls to measure and control the required flow rates

• Microprocessor digital temperature control


Click on the image to view a larger photo of the instrument.

K12230 High Temperature Oxidation Bath, Convertible
High temperature liquid bath for oxidation stability and corrosiveness tests at temperatures of up to 200°C. Available in different configurations for convertibility between several oxidation stability and corrosivity test methods including Cummins oxidation test. Removable rack/top plate assemblies remove and install with minimum effort to easily convert the bath between test methods. For most test methods, twelve sets of glassware can be accommodated in each rack assembly. Select flowmeters or digital mass flow control to maintain air flow at the required rates. Microprocessor PID control provides quick temperature stabilization without overshoot, and the bath is protected by an over-temperature control circuit that interrupts power should bath temperature exceed a programmed cut-off point. Dual LED displays provide actual and setpoint temperature values in °C/°F format. Communication software (RS232, etc.) ramp-to-set and other enhanced features are available as extra cost options. Contact your Koehler representative for information.


Specifications
Conforms to the specifications of *: ASTM D943, D2274, D2440, D2893, D4310, D4636, D5968; UOT**, DIN 51586, DIN 51587, DIN 51394; FTM 791-5307, FTM 791-5308
*With the appropriate glassware rack and flow control equipment installed.
**Modified versions of this equipment are available for UOT test method.

Capacity: Twelve (12) sets of glassware
(Ten (10) sets of glassware for ASTM D5968, FTM 791-5307, and FTM 791-5308)

Temperature Range: Ambient to 200°C

Temperature Control Accuracy: 0.2°F (0.1°C)

Bath Medium: Silicone heat transfer fluid

Flow Rate: As specified for ASTM or applicable specifications

Electrical Requirements
115V 50/60Hz, Single Phase, 27.3A
220-240V 50/60Hz, Single Phase, 14.6A

Dimensions lxwxh,in.(cm)
Bath (without glassware): 25.5x24x42 (65x61x107)

Shipping Information (without glassware)
Shipping Weight: 213 lbs (96.6kg)
Dimensions: 29 Cu. ft.

Ordering Information
Catalog
Number
Product Description Electrical Requirements
K12230 High Temperature Oxidation Bath, Convertible 115V 50/60Hz
K12239 High Temperature Oxidation Bath, Convertible 220-240V 50/60Hz

Accessories
Catalog
Number
Product Description
ASTM D943, D4310, and D2274 Accessories
For ASTM D2274, order one each K122-0-18 Oxygen Delivery Tube, K122-0-19 Oxidation Test Tube, and K122-0-20 Condenser for each cell.
K12281 Oxidation Cell Assembly for ASTM D943 and D4310.
Includes oxidation cell, condenser, oxygen delivery tube, thermometer bracket, oil level indicator strip, syringe sampling tube, sampling tube holder, spacer,
K122-0-18 Oxygen Delivery Tube
K122-0-19 Oxidation Test Tube
K122-0-20 Condenser
K122-0-21 Thermometer Bracket
K122-0-22 Oil Level Indicator Strip
K122-0-23 Syringe Sampling Tube Holder
K122-0-27 PTFE Stopper
K122-0-28 Syringe Sampling Spacer
K122-0-30 Syringe Sampling Tube
AS568-009-V14 O-Rings
Iron-Copper Catalyst. For ASTM D943 and D4310.
K12210 Catalyst Coil
Low-metalloid steel wire and electrolytic copper wire wound in a double spiral conforming to ASTM specifications. Packed in a sealed glass tube with a nitrogen atmosphere. Ready for use.
K24000 Wire Coiling Mandrel
Mounts on bench for winding steel and copper wire into catalyst coils meeting ASTM specifications.
K12250 Steel Wire
Low metalloid steel wire, 0.0625" (1.59mm) diameter, for catalyst coils. Supplied in 1000 ft (304.8m) lengths.
K12260 Copper Wire
Electrolytic copper wire, 0.064" (1.63mm) diameter, for catalyst coils. Supplied in 1000 ft (304.8m) lengths.
380-100-001 Silicone Carbide Paper
Used to polish steel and copper wire prior to winding into catalyst coils. 100 grit.
Thermometers
250-002-001 Oxidation Cell Thermometer. For ASTM D943 and D4310.
Range: 80 to 100°C.
250-000-40C ASTM 40C Thermometer. For constant temperature baths.
Range: 72 to 126°C.
ASTM D4636, D5968, D6594 and FTM 791-5307
K351-0-1 Sample Tube
K351-0-2 Sample Tube Head
K351-0-3 Air Tube
K351-0-4 Thermocouple Tube
K351-0-5 Condenser, Allihn Type
K351-0-7 Spacer
K351-0-8 PTFE Adapter
K351-0-13 Oil Sampling Tube (for D5968 and FTM 791-5307)
K351-0-14 Specimen Hanger (for D6594)
K293-0-12 Thermocouple, Type J
K29310 Digital Thermometer
Microprocessor based digital thermocouple thermometer with ten-channel input. Monitors Type J thermocouples from sample tubes.
K35090 Test Panel Assembly Fixture
Holds square-shaped metal specimens for tying with cord (for FTM 791-5307 and FTM 791-5308)
K35095 Test Panel Assembly Fixture
Holds square-shaped metal specimens for tying with cord (for ASTM D5968)
FTM 791-5308
K350-0-23 Test Tube
K350-0-24 Air Tube
K350-0-25 Condenser
K35090 Test Panel Assembly Fixture
Holds square-shaped metal specimens for tying with cord.
Washer Shaped Specimens for ASTM D4636 Standard Procedure and for FTM 791-5307
K35110 Bronze
K35120 Mild Steel
K35130 Aluminum Alloy
K35140 Magnesium
K35150 Steel M50
K35160 Silver
K35170 Titanium
Square Shaped Specimens for ASTM D4636 Alternate Procedure and for FTM 791-5308
K35010 Copper
K35020 Mild Carbon Steel
K35030 Aluminum Alloy
K35040 Magnesium Alloy
K35050 Cadmium Plated Steel
K35060 Silver
K35070 Solid Cadmium (non standard)
K35080 Titanium (non standard)
Square Shaped Specimens for ASTM D5968 and D6594
K35010 Copper
K35011 Lead
K35012 Tin
K35013 Phosphor Bronze
Polishing Materials
380-150-001 Silicone Carbide Paper, 150-grit.
Pack of 50 sheets.
380-240-001 Silicone Carbide Paper, 240-grit.
Pack of 50 sheets.
380-150-000 Silicone Carbide Grain, 150-grit.
1 lb package.
When inquiring about NIST traceable certified thermometers, please refer to the catalog number for the corresponding thermometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01C ASTM 1C Thermometer would be 251-004-01C ASTM 1C Certified Thermometer.

www.koehlerinstrument.com