KI-10401 Oxidation Stability of Fuels, Solid Block Baths

Test Method
Provides an indication of the tendency of gasoline and aviation fuels to form gum in storage. The sample is oxidized inside a stainless steel pressure vessel initially charged with oxygen at 100psi (689kPa) and heated in a solid block bath. The amount of time required for a specified drop in pressure (gasoline) or the amount of gum and precipitate formed after a specific aging period (aviation fuels) is determined.

Features and Benefits
• Conforms to ASTM D525, D873, ISO 7536 and related specifications

• Available in two or four-unit configurations

• Choice of water or solid block heating baths

• Oxidation pressure vessel incorporates burst disk assembly


Click on the image to view a larger photo of the instrument.

KI-10401 Oxidation Stability of Fuels, Solid Block Baths
Insulated aluminum block baths available in two or four-unit capacity. Baths feature microprocessor temperature control with built-in overtemperature protection and dual LED displays for setpoint and actual temperature values in °C/°F format. The solid block design offers operating advantages over the boiling water bath, and meets temperature control and other requirements of ASTM and related methods. It should be noted, however, that many applicable specifications for this test method call for a liquid bath medium. Housed in an insulated steel cabinet with chemical-resistant polyurethane enamel finish. Includes lids for pressure vessel ports. Order thermometer separately.

Communications software (RS232, etc.) ramp-to-set and other enhanced features are available as extra cost options. Contact your PSSC representative for information.

Specifications
Conforms to the specifications of: ASTM D525, D873; IP 40, IP 138; ISO 7536; DIN 51780, 51799; FTM 791-3352, 791-3354; NF M 07-012, 07-013

Maximum Temperature
250°F (121°C)

Solid block baths meet temperature control and other requirements of ASTM and related methods. While the aluminum block design offers operating advantages over the standard boiling water bath, it should be noted that many applicable specifications for this test call for a liquid bath medium. Please refer to the test method for the specific requirements.

Ordering Information
Catalog
Number
Capacity Electrical Requirements Heater Range Dimensions
lxwxh,in.(cm)
KI-10401 2 vessels 115V 50/60Hz, 12A 0-1300W 15x10x17
(38x25x43)
KI-10491 220-240V 50/60Hz, 6A
KI-10403 4 vessels 115V 50/60Hz, 22A 0-2500W 24x10x17
(61x25x43)
KI-10493 220-240V 50/60Hz, 11A

Accessories
Catalog
Number
Product Description
KI-10540 Glass Sample Container and Cover with pour out spout
KI-10510 Gasket.
Replacement composition gasket for KI-10500 Oxidation Pressure Vessel.
KI-10551 Pressure Line.
For pressurizing Oxidation Pressure Vessel. 6 ft. (1.83m) long, with quick release coupling for needle valve on pressure vessel and threaded fitting for oxygen tank.
KI-10556 Oxygen Manifold Pressure Relief System.
Connects to oxygen source to prevent overcharging of vessel. Equipped with relief valve to vent at 125psi and 300 series stainless steel 150psi burst disk assembly. Constructed from 300 series stainless steel. Cleaned for oxygen service.
KI-10520 Wrench.
For tightening seal on Oxidation Pressure Vessel.
KI-10530 Table Socket.
Installs in benchtop to aid in tightening seal on Oxidation Pressure Vessel.
KI-10560 Bronze Tubing.
For connecting pressure recorder to vessel. Flexible seamless helical tubing with protective armor braid and connections. 5 ft (1.52m) long.
KI-10525 Burst Disk Assembly.
Retrofit kit for Oxidation Pressure Vessel without burst disk assembly.
250-000-22F ASTM 22F Thermometer
Range: 204 to 218°F
250-000-22C ASTM 22C Thermometer
Range: 95 to 103°C
308-000-005 Recorder Charts, Pack of 100.
308-001-02R Recorder Cartridge Pen, Red
308-001-02B Recorder Cartridge Pen, Blue
When inquiring about NIST traceable certified thermometers, please refer to the catalog number for the corresponding thermometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01C ASTM 1C Thermometer would be 251-004-01C ASTM 1C Certified Thermometer.

www.pssc.org